Flow Case Switch Failing

odd that it's failing, I have created case switch that works in other flows... am I missing something?

 

For me to troubleshoot I have super simplified the case and actions to just a notify.

I get rows from SQL (filtering to 1 row for this troubleshoot)

I am switching case based on a location field (in this case the number 10)

if the switch is gone, everything else has been working... but that doesn't help when there may be hundreds of rows of data.2018-06-13_15-16-40.jpg

 

1 ACCEPTED SOLUTION

Accepted Solutions

I found the issue.

the switch will only work with columns of datatype INT....

not sure exactly why it was failing, but I altered the view to change the value I was switching on to INT from varchar and it worked fine...2018-06-14_8-09-54.jpg

View solution in original post

9 REPLIES 9

It isn't the switch that is failing as the notification is failing. Ohterwise the notifdication step wouldn't run. Can you show the notification action details in edit mode.

Yeah, it looks like it's going through the switch, but I've removed the switch and it's worked... I'll attempt again real quick and send the results

 

here it is currently

2018-06-14_7-12-52.jpg

all I did here was move the notification out of the switch branch and it worked fine.

while the exact same notification (this time in location 15) failed while inside the switch branch

2018-06-14_7-16-46.jpg

Notification.PNG 

I just reproduced this problem. i would add this to the I found a bug section

 

In the meanwhile I would use send an Email actions

I'll move it over to a bug thread, but this notification wasn't the only thing failing inside the switch.

the notifications were just used for troubleshooting.

 

what baffles me the most is I have a working switch I also made yesterday in a different flow.

 

2018-06-14_7-44-50.jpg2018-06-14_7-46-20.jpg

That doiesn't make sense. I'm sure I have sent emails inside a switch before.

 

Can you try exporting the flow and then importing it as a new flow. That way the connections should be reset.,

it doesn't even have to be emails

2018-06-14_7-57-54.jpg2018-06-14_7-58-32.jpg

I found the issue.

the switch will only work with columns of datatype INT....

not sure exactly why it was failing, but I altered the view to change the value I was switching on to INT from varchar and it worked fine...2018-06-14_8-09-54.jpg

View solution in original post

I've been having issues with this all day. So glad I found this! Thank you!

Helpful resources

Announcements
Process Advisor

Introducing Process Advisor

Check out the new Process Advisor community forum board!

MPA User Group

Welcome to the User Group Public Preview

Check out new user group experience and if you are a leader please create your group

V3_PVA CAmpaign Carousel.png

Community Challenge - Giveaways!

Participate in the Power Virtual Agents Community Challenge

Carousel 2021 Release Wave 2 Plan 768x460.jpg

2021 Release Wave 2 Plan

Power Platform release plan for the 2021 release wave 2 describes all new features releasing from October 2021 through March 2022.

Top Kudoed Authors
Users online (3,304)